Technische Infos Kabel

Loading...
  1. What's the orientation of the XLR angle plugs?

    The female Neutrik XLR connector has five selectable cable outlet positions Read more...
  2. What's the orientation of the LEMO angle plugs?

    What's the orientation of the LEMO angle plugs? There are two different types of LEMO angle connectors: one with a fixed direction of the cable outlet and one where the direction can be configured. The standard version has the cable outlet always in position 5, if you hold the connector with the red dot or the coding nose up, the cable outlet points downwards. The new variant "Anglissimo" can Read more...
  3. How is the clear shrink tube on the cable used?

    The idea is that the customer can easily label the cables. For this purpose, a piece of clear heat shrink tube is pushed on during assembly, as this is not possible afterwards. You can mark your cable with a label printer or a piece of tape and then shrink the shrinking tube over it, so that the marking remains permanently on the cable and is Read more...
  4. How is the length of the cable measured?

    How is the length of the cable measured? The cable length specified with the articles or requested by the customer is always measured from the end of one plug to the end of the other plug, for plugs with a bend relief it is the rear clamping nut. The plugs are not added to the cable length. The length has a tolerance of 1-2cm, due to the manufacturing process.   Read more...
  5. Which type of wires are used for the cables?

    Which type of wires are used for the cables? All cables for power and the various signal cables are available with different types of wires: Standard cables The standard cable is a special, resistant electronic cable with a polyurethane outer sheath. This cable is resistant to mechanical stress without leaving kinks or knots in the cable. This cable is available in various cross-sections Read more...
  6. What's the purpose of the ferrites on the cables?

    What's the purpose of the ferrites on the cables? Electronic devices can cause high-frequency interference - this applies both to the camera with accessories and to other devices on set. These interferences propagate via connected cables. In order to limit them to a legal level, the cables are fed through ferrite beads which have a damping effect. In simple terms, cables connected to the camera Read more...
  7. Wie ist die Pol Belegung des 2pol Lemo Steckers?

    Wie ist die Pol Belegung des 2pol Lemo Steckers? Beim dem u.a. an Arri Kameras als 12V Ausgang oder bei Teradek als Eingang verwendeten 2pol Lemo Stecker gibt es zwei verschiedene Varianten der Polbelegung. Arri verwendet den Stecker so, dass auf Pin #1 GROUND ("Minuspol") und auf Pin 2 die Spannung ("Pluspol") anliegt. Der Pin #1 ist mit einem roten Punkt auf dem Stecker bzw. der Buchse Read more...